Bulk Adsorbents Silica Gel Column Chromatography

Country/Region china

Company SORBEAD INDIA COMPANY

Categories Silica Gel Desiccant Dehumidifier

Update 2011-09-27 14:59:34

ICP License Issued by the Chinese Ministry

Contact Now

Silica Gel Column Chromatography Description

All chromatographic methods -with the exception of TLC- use columns for the separation process. Column chrom-atography has found its place in many laboratories for preparative purposes as well as for reaction control in organic syntheses. The importance of column chromatography is mainly due to following factors:
Simple packing procedure
Low operating pressure
Low expense for instrumentation
Column chromatography is separated into two categories, depending on how the solvent flows down the column. If the solvent is allowed to flow down the column by gravity, or percolation, it is called gravity column chromatography. If the solvent is forced down the column by positive air pressure, it is called flash chromatography, a "state of the art" method currently used in organic chemistry research laboratories.
The Adsorbent
Silica gel (SiO2) and alumina (Al2O3) are two adsorbents commonly used by the organic chemist for column chromatography. These adsorbents are sold in different mesh sizes, as indicated by a number on the bottle label: silica gel 60” or silica gel 230-400” is a couple examples. This number refers to the mesh of the sieve used to size the silica, specifically, the number of holes in the mesh or sieve through which the crude silica particle mixture is passed in the manufacturing process.
Adsorbent particle size affects how the solvent flows through the column. Smaller particles (higher mesh values) are used for flash chromatography; larger particles (lower mesh values) are used for gravity chromatography. For example, 70230 silica gels are used for gravity columns and 230400 mesh for flash columns.
Grades Available
35-70mesh
60-120 mesh
70-230 mesh
100-200 mesh
200-400 mesh
230-400 mesh
400-800 mesh
Features and Benefits:
High resolution
Batch to Batch reproducible results
Excellent flow rates
Direct scalability
Typical Data of Silica gel Column Grade Adsorbents
Iron Content- < 0.02%
Chloride Content- < 0.10%
Loss on Drying- <3%
pH (10% suspension)-70.5
Surface Area- 400600 m2/gm

Product Tags:

drying out silica gel

      

silica gel spare parts

      

silica gel for transformer

      
China Bulk Adsorbents Silica Gel Column Chromatography

Bulk Adsorbents Silica Gel Column Chromatography Images

Send your message to this supplier
From:
Enter your email please.
To: SORBEAD INDIA COMPANY
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0